              PLC企業資訊
                Brocade和Cisco光纖交換機級聯配置
                發布者:brocade  發布時間:2013-01-30 16:58:35

                    北京恒正同創科技有限公司,博科Brocade光纖交換機金牌代理商,我們希望不僅為廣大用戶
                提供優質的產品,更能在產品售后服務上令您滿意,免除您的后顧之憂。產品動態詳情請登錄公司官網:www.brocader.com.cn

                Brocade
                Cisco光纖交換機級聯配置

                1.配置異構交換機平臺協同工作模式

                Cisco 9120配置過程

                激活前8個端口
                switch# config t
                Enter configuration commands, one per line.  End with CNTL/Z.
                switch(config)#interface fc1/1-8
                switch(config-if)# no shutdown switch(config-if)# end
                配置交換機協同工作模式
                switch# config t
                Enter configuration commands, one per line.  End with CNTL/Z.
                switch(config)# vsan database
                switch(config-vsan-db)# vsan 1 interop
                switch(config-vsan-db)# end

                配置domain ID
                switch# config t
                Enter configuration commands, one per line.  End with CNTL/Z.
                switch(config)# fcdomain domain 100 preferred vsan 1
                switch(config)# end

                激活VSAN
                switch# config t
                Enter configuration commands, one per line.  End with CNTL/Z.
                switch(config)# vsan database
                switch(config-vsan-db)# vsan 1 suspend
                switch(config-vsan-db)# no vsan 1 suspend
                switch(config-vsan-db)# end

                察看修改之后的系統配置信息
                switch# show running
                version 2.0(2b)
                vsan database
                  vsan 1 interop 1
                fcdomain domain 100 preferred vsan 1
                fcdomain fcid persistent vsan 1
                boot kickstart bootflash:/m9100-s1ek9-kickstart-mz.2.0.2b.bin
                boot system bootflash:/m9100-s1ek9-mz.2.0.2b.bin
                kernel core target 0.0.0.0
                kernel core limit 1

                snmp-server user admin network-admin auth md5 0xeec64ba2afbe9b65e13b23882ac6ae05
                 priv 0xeec64ba2afbe9b65e13b23882ac6ae05 localizedkey
                username admin password 5 $1$V3smTQpb$MTvub69DkVBxdCt9BsEDB1  role network-admin
                callhome
                  switch-priority 7
                snmp-server enable traps license
                interface mgmt0
                  ip address 192.168.70.139 255.255.255.0

                interface fc1/1
                  no shutdown

                interface fc1/2
                  no shutdown

                interface fc1/3
                  no shutdown

                interface fc1/4
                  no shutdown

                interface fc1/5
                  no shutdown

                interface fc1/6
                  no shutdown

                interface fc1/7
                  no shutdown

                interface fc1/8
                  no shutdown

                interface fc1/9
                interface fc1/10
                interface fc1/11
                interface fc1/12
                interface fc1/13
                interface fc1/14
                interface fc1/15
                interface fc1/16
                interface fc1/17
                interface fc1/18
                interface fc1/19
                interface fc1/20
                switch#

                察看端口連接狀態信息
                switch# show interface brief

                -------------------------------------------------------------------------------
                Interface  Vsan   Admin  Admin   Status          FCOT   Oper  Oper   Port
                                  Mode   Trunk                          Mode  Speed  Channel
                                         Mode                                 (Gbps)
                -------------------------------------------------------------------------------
                fc1/1      1      auto   on      up               swl    F       2    --
                fc1/2      1      auto   on      up               swl    F       2    --
                fc1/3      1      auto   on      up               swl    E       2    --
                fc1/4      1      auto   on      notConnected     swl    --           --
                fc1/5      1      FX     --      notConnected     swl    --           --
                fc1/6      1      FX     --      notConnected     swl    --           --
                fc1/7      1      FX     --      notConnected     swl    --           --
                fc1/8      1      FX     --      notConnected     swl    --           --
                fc1/9      1      FX     --      sfpAbsent        --     --           --
                fc1/10     1      FX     --      sfpAbsent        --     --           --
                fc1/11     1      FX     --      sfpAbsent        --     --           --
                fc1/12     1      FX     --      sfpAbsent        --     --           --
                fc1/13     1      FX     --      sfpAbsent        --     --           --
                fc1/14     1      FX     --      sfpAbsent        --     --           --
                fc1/15     1      FX     --      sfpAbsent        --     --           --
                fc1/16     1      FX     --      sfpAbsent        --     --           --
                fc1/18     1      FX     --      sfpAbsent        --     --           --
                fc1/19     1      FX     --      sfpAbsent        --     --           --
                fc1/20     1      FX     --      sfpAbsent        --     --           --

                 


                刀片中心光纖交換機模塊配置

                禁止交換機
                brocadessm:USERID> switchdisable

                修改Domain ID
                brocadessm:USERID> configure

                Configure...

                  Fabric parameters (yes, y, no, n): [no] yes

                    Domain: (1..239) [1] 99
                    R_A_TOV: (4000..120000) [10000]
                    E_D_TOV: (1000..5000) [2000]
                    WAN_TOV: (0..30000) [0]
                    MAX_HOPS: (7..19) [7]
                    Data field size: (256..2112) [2112]
                    Sequence Level Switching: (0..1) [0]
                    Disable Device Probing: (0..1) [0]
                    Suppress Class F Traffic: (0..1) [0]
                    Switch PID Format: (1..2) [1]
                    Per-frame Route Priority: (0..1) [0]
                    Long Distance Fabric: (0..1) [0]
                    BB credit: (1..27) [16]

                  Insistent Domain ID Mode (yes, y, no, n): [no]
                  Virtual Channel parameters (yes, y, no, n): [no]
                  Zoning Operation parameters (yes, y, no, n): [no]
                  RSCN Transmission Mode (yes, y, no, n): [no]
                  Arbitrated Loop parameters (yes, y, no, n): [no]
                  System services (yes, y, no, n): [no]
                  Portlog events enable (yes, y, no, n): [no]
                  ssl attributes (yes, y, no, n): [no]
                  http attributes (yes, y, no, n): [no]
                  snmp attributes (yes, y, no, n): [no]
                  rpcd attributes (yes, y, no, n): [no]
                  cfgload attributes (yes, y, no, n): [no]
                  webtools attributes (yes, y, no, n): [no]
                WARNING: The domain ID will be changed. The port level zoning may be affected

                brocadessm:USERID> msPlMgmtDeactivate
                Switch is in Offline state.

                修改協同工作模式
                brocadessm:USERID> interoper mode 1
                The switch effective configuration will be lost when the operating mode is changed; do you want to continue? (yes, y, no, n): [no] y
                Interopmode is enabled

                Note: It is recommended that you reboot this switch for the new change to take effect.

                重新引導交換機
                brocadessm:USERID> fastboot
                 Broadcast message from root (pts/0) Tue Jun 13 10:07:45 2006... The system is going down for reboot NOW !! USERID
                Password:
                Please change your passwords now.
                Use Control-C to exit or press 'Enter' key to proceed.
                Password was not changed. Will prompt again at next login
                until password is changed.
                brocadessm:USERID>

                激活交換機
                brocadessm:USERID> switchenable

                察看修改配置之后的交換機狀態

                brocadessm:USERID> switchshow
                switchName: brocadessm
                switchType: 22.0
                switchState: Online  
                switchMode: Interop
                switchRole: Principal
                switchDomain: 99
                switchId: fffc63
                switchWwn: 10:00:00:05:1e:02:78:c6
                zoning:         OFF
                switchBeacon: OFF

                Area Port Media Speed State
                ==============================
                  0   0   id    2G   No_Light 
                  1   1   cu    2G   Online    F-Port  21:00:00:14:5e:24:a9:04
                  2   2   cu    2G   Online    F-Port  21:00:00:14:5e:24:a9:36
                  3   3   cu    2G   Online    F-Port  21:00:00:14:5e:24:a9:7a
                  4   4   cu    2G   Online    F-Port  21:00:00:14:5e:24:a9:b6
                  5   5   cu    2G   Online    F-Port  21:00:00:14:5e:24:a9:28
                  6   6   cu    2G   Online    F-Port  21:00:00:14:5e:24:aa:f6
                  7   7   cu    2G   Online    F-Port  21:00:00:14:5e:24:aa:f0
                  8   8   cu    2G   Online    F-Port  21:00:00:14:5e:24:a9:38
                  9   9   cu    2G   No_Light 
                 10  10   cu    2G   No_Light 
                 11  11   cu    2G   No_Light 
                 12  12   cu    2G   No_Light 
                 13  13   cu    2G   No_Light 
                 14  14   cu    2G   No_Light 
                 15  15   id    2G   Online    E-Port  20:01:00:0d:ec:06:b4:41 (downstream)
                 
                 


                2.
                劃分zone
                Cisco 9120
                劃分
                zone
                 
                察看fabric連接設備port wwn 信息

                switch# show fcns database vsan 1
                VSAN 1:
                --------------------------------------------------------------------------
                FCID        TYPE  PWWN                    (VENDOR)        FC4-TYPE:FEATURE
                --------------------------------------------------------------------------
                0x630100    N     21:00:00:14:5e:24:a9:04                 scsi-fcp
                0x630200    N     21:00:00:14:5e:24:a9:36                 scsi-fcp
                0x630300    N     21:00:00:14:5e:24:a9:7a                 scsi-fcp
                0x630400    N     21:00:00:14:5e:24:a9:b6                 scsi-fcp
                0x630500    N     21:00:00:14:5e:24:a9:28                 scsi-fcp
                0x630600    N     21:00:00:14:5e:24:aa:f6                 scsi-fcp
                0x630700    N     21:00:00:14:5e:24:aa:f0                 scsi-fcp
                0x630800    N     21:00:00:14:5e:24:a9:38                 scsi-fcp
                0x640000    N     20:07:00:a0:b8:21:19:9f (SymBios)       scsi-fcp:both
                0x640100    N     20:06:00:a0:b8:21:19:9f (SymBios)       scsi-fcp:both

                Total number of entries = 10

                創建zone
                分別創建2zone,前4個刀片服務器與DS4300 2個控制器組成的zone,第4到第8個刀片服務器與DS4300 2個控制器組成的zone。

                switch# config t Enter configuration commands, one per line.  End with CNTL/Z.
                switch(config)# zone name blade_hs20_1-4 vsan 1

                switch(config-zone)# member pwwn 21:00:00:14:5e:24:a9:04

                switch(config-zone)# member pwwn 21:00:00:14:5e:24:a9:36

                switch(config-zone)# member pwwn 21:00:00:14:5e:24:a9:7a

                switch(config-zone)# member pwwn 21:00:00:14:5e:24:a9:b6

                switch(config-zone)# member pwwn 20:07:00:a0:b8:21:19:9f

                switch(config-zone)# member pwwn 20:06:00:a0:b8:21:19:9f
                switch(config-zone)#exit
                 switch(config)# zone name blade_hs20_5-8 vsan 1
                switch(config-zone)# member pwwn 21:00:00:14:5e:24:a9:28

                switch(config-zone)# member pwwn 21:00:00:14:5e:24:aa:f6

                switch(config-zone)# member pwwn 21:00:00:14:5e:24:aa:f0

                switch(config-zone)# member pwwn 21:00:00:14:5e:24:a9:38

                switch(config-zone)# member pwwn 20:07:00:a0:b8:21:19:9f

                switch(config-zone)# member pwwn 20:06:00:a0:b8:21:19:9f
                 
                創建
                zoneset
                switch(config-zone)# zoneset name ds4300_blade vsan 1

                switch(config-zoneset)# member Blade_Hs20_1-4
                switch(config-zoneset)# member Blade_Hs20_5-8
                switch(config-zoneset)# end
                激活
                zoneset switch# config t Enter configuration commands, one per line.  End with CNTL/Z.
                switch(config)# zoneset activate name ds4300_blade vsan 1 Zoneset activation initiated. check zone status
                 
                察看激活的zone信息

                switch# show zone active vsan 1
                zone name blade_hs20_1-4 vsan 1
                * fcid 0x630100 [pwwn 21:00:00:14:5e:24:a9:04]
                * fcid 0x630200 [pwwn 21:00:00:14:5e:24:a9:36]
                * fcid 0x630300 [pwwn 21:00:00:14:5e:24:a9:7a]
                * fcid 0x630400 [pwwn 21:00:00:14:5e:24:a9:b6]
                * fcid 0x640000 [pwwn 20:07:00:a0:b8:21:19:9f]
                * fcid 0x640100 [pwwn 20:06:00:a0:b8:21:19:9f]

                zone name blade_hs20_5-8 vsan 1
                * fcid 0x630500 [pwwn 21:00:00:14:5e:24:a9:28]
                * fcid 0x630600 [pwwn 21:00:00:14:5e:24:aa:f6]
                * fcid 0x630700 [pwwn 21:00:00:14:5e:24:aa:f0]
                * fcid 0x630800 [pwwn 21:00:00:14:5e:24:a9:38]
                * fcid 0x640000 [pwwn 20:07:00:a0:b8:21:19:9f]
                * fcid 0x640100 [pwwn 20:06:00:a0:b8:21:19:9f]
                 

                保存系統配置信息
                switch# copy running startup
                [########################################] 100%


                刀片中心光纖交換機模塊查看zone信息

                brocadessm:USERID> cfgshow
                Defined configuration:
                 no configuration defined

                Effective configuration:
                 cfg: ds4300_blade 
                 zone: blade_hs20_1-4 
                  21:00:00:14:5e:24:a9:04
                  21:00:00:14:5e:24:a9:36
                  21:00:00:14:5e:24:a9:7a
                  21:00:00:14:5e:24:a9:b6
                  20:07:00:a0:b8:21:19:9f
                  20:06:00:a0:b8:21:19:9f
                 zone: blade_hs20_5-8 
                  21:00:00:14:5e:24:a9:28
                  21:00:00:14:5e:24:aa:f6
                  21:00:00:14:5e:24:aa:f0
                  21:00:00:14:5e:24:a9:38
                  20:07:00:a0:b8:21:19:9f
                  20:06:00:a0:b8:21:19:9f

                如上命令輸出所示,Cisco 9120zone 信息已經同步到刀片中心的交換機模塊。

                系統配置完成。

                 

                版權聲明PLC信息網轉載作品均注明出處,本網未注明出處和轉載的,是出于傳遞更多信息之目的,并不意味 著贊同其觀點或證實其內容的真實性。如轉載作品侵犯作者署名權,或有其他諸如版權、肖像權、知識產權等方面的傷害,并非本網故意為之,在接到相關權利人通知后將立即加以更正。聯系電話:0571-87774297。