                HGX22e/190-4S天行健直供原廠德國GEA BOCK5匹中高溫船用壓縮機
                發布者:txj52888  發布時間:2022-06-14 11:39:47

                HGX22e/190-4S福州天行健17年專業直供原廠德國GEA BOCK船用壓縮機及壓縮機零部件

                原裝德國Bizter船用壓縮機及壓縮機零部件

                德國原裝Roller船用風機及風機零部件


                Semi-hermetic suction gas-cooled reciprocating compressor in compact design. The best possible serviceability is provided by means of a replaceable drive motor, among other things. The compressor stands out due to its outstanding running comfort and efficient operating performance. The suction shut-off valve can be rotated by 90° in each instance. Dependable mechanism lubrication is guaranteed by means of an oil pump which is independent of rotating direction, as well as a large-volume oil sump. An electronic motor protection uses PTC sensors in series to monitor the winding temperature and, if desired, the discharge gas temperature.
                Colour: blue (RAL 5000)


                Technical data

                HGX22e/190-4 S
                Application Refrigeration & AC
                Compressor refrigeration capacity 13.50 kW
                Power consumption 4.92 kW
                Current draw (400 V) 8.27 A
                Mass flow 0.127 kg/s

                at following operating condition:
                Refrigerant R404A, R507
                Reference temperature Dew point
                Evaporating temperature 5.0 °C
                Condensing temperature 50.0 °C
                Supply frequency 50 Hz
                Voltage 400 V
                Suction gas temperature 20 °C
                Subcooling (outside cond.) 0 K
                Number of cylinders / Bore / Stroke 2 / 55 mm / 40 mm
                Displacement 50/60 Hz (1450/1740 1/min) 16,50 / 19,80 m3/h
                Voltage 1) 220-240V Δ / 380-420V Y -3- 50Hz
                265-290V Δ / 440-480V Y -3- 60Hz
                Max. working current 2) 16.2 / 9.4 A
                Max. power consumption 2) 5.6 kW
                Starting current (rotor blocked) 2) 87.0 / 50.0 A
                Motor protection INT69 G
                Protection terminal box IP 66
                Weight 75 kg
                Frequency range 3) 30 -70 Hz
                Max. permissible overpressure (g) (LP/HP) 4) 19 / 28 bar
                Connection suction line SV 22 mm - 7/8 "
                Connection discharge line DV 16 mm - 5/8 "
                Lubrication Oil pump
                Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A BOCKlub E55
                Oil type R22 BOCKlub A46
                Oil charge 1,1 Ltr.
                Dimensions Length / Width / Height 468 / 240 / 315 mm
                Sound power level LWA 5) 70 db(A) @ -35/+40 °C
                69 db(A) @ -10/+45 °C
                67 db(A) @ +5/+50 °C
                Sound pressure level LpA 5) 58 db(A) @ -35/+40 °C
                57 db(A) @ -10/+45 °C
                55 db(A) @ +5/+50 °C

                Scope of supply

                Semi-hermetic two cylinder reciprocating compressor with drive motor
                Single-section compressor housing with hermetically integrated electric motor

                Winding protection with PTC resistor sensors and electronic trigger unit INT69 G
                115-230 V AC, 50/60 Hz, IP00

                Oil pump

                Possibility for connection of oil pressure safety switch MP55

                Possibility of connection of oil level controllers ESK, Traxoil, AC+R or CARLY 6)

                Oil charge:
                HG: BOCKlub A46
                HGX: BOCKlub E55

                Sight glass

                Suction and discharge line valve

                Inert gas charge

                Accessories

                Oil sump heater
                110-240 V - 1 - 50/60 Hz, 50-120 W, IP66
                PTC heater self-regulating

                USB converter for INT69 G Diagnose 7)

                Thermal protection thermostat per cylinder cover 8)

                Oil pressure safety switch MP55 230 V - 1 - 50/60 Hz, IP20 7)

                INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable)

                DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 7)

                Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 7)

                Additional fan
                230 V AC - 1 - 50 Hz, 97 W, IP44
                230 V AC - 1 - 60 Hz, 128 W 7)

                4 anti-vibration pads enclosed

                Special voltage and/or frequency (on request)

                Notes
                1) Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request
                All data are based on voltage rms values
                2) - The stated value for the max. power consumption is valid for the adjusted power supply.
                - Starting current (rotor blocked):
                • Part winding (PW) motors: Winding 1 / Winding 1+2
                • Delta/Star (Δ/Y) motors: Δ / Y
                - Take account of the max. operating current / max. power consumption for designing motor contractors, feed lines, fuses and motor protection switches. Motor contractors: Consumption category AC3.
                3) The maximum permissible working current of the compressor (Imax) must not be exceeded. Take account of the guidelines for use of frequency inverter (see compressor assembly instruction or selection software).
                4) LP = Low pressure
                HP = High pressure
                5) Declared dual-number noise emission values are in accordance with ISO 4871. The corresponding uncertainty to the sound power level is KWA = 2,5 dB and to the sound pressure level is KpA = 2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the standard rating points according to EN 12900.
                • A-weighted sound power level LWA (re 1 pW), in decibel. To determine the values, measurement methods of the ISO 3740 standard with accuracy class 2 or higher were used .
                • A-weighted sound pressure level LpA (re 20 μPa), in decibel. The values are calculated from the sound power level in accordance with ISO 11203: LpA = LWA - Q2 at a distance of d = 1m to the reference box.
                6) Only with additional adapter possible